Power Xplorer / Power Guide / Power Visa
A quick reference guide for the PowerXplorer / PowerGuide/
PowerVisa product family. It is recommended that the user still
be familiar with the complete User’s Guides for the respective
products, as it contains more detailed information about all
of the functions, as well as the specifications and accessories.
Quick Reference Guide
Dranetz
1000 New Durham Road
Edison,
New Jersey 08818
Telephone 1-800-372-6832 or 732-287-3680
Fax 732-248-1834 www.dranetz.com
Przeglądanie stron 0
1 2 3 4 5 6 ... 43 44

Podsumowanie treści

Strona 1

Power Xplorer / Power Guide / Power Visa A quick reference guide for the PowerXplorer / PowerGuide/ PowerVisa product family. It is recommended

Strona 2 - WARNING

9 Connecting to AC Power Source Power The PX5 AC adapter can be connected to a 90-265V specifications ac power input source. CAUTION Always se

Strona 3 - ADVERTENCIA

10 AC power PX5 can be operated from a 50/60 Hz, 120/230V AC Source power source with or without the battery pack installed. • Voltage range, 120/

Strona 5 - WARNUNG

12 1. Voltage and Current Connections – there are four differential voltage and four differential current channels, which can be wired to measure a v

Strona 6 - Safety Summary

13 MAKING CONNECTIONS WARNING Death, serious injury, or fire hazard could result from improper connection of this instrument. Read and understand

Strona 7 - Safety Precautions

14 Connecting Voltage Measurement Cables Measurement cable set Description: Voltage measurement cables are provided as standard accessories and are

Strona 8 - TABLE OF CONTENTS

15 --------------------------------------------------------------------------------- PX5 can monitor the following power configurations: • Single ph

Strona 9 - Getting Started

16 3 Phase, Four Wire Wye Channels A, B, and C are connected to voltage and current probes. The neutral is connected to common and is the reference fo

Strona 10

17 3 Phase (Floating or Grounded) Delta In this power connection, the PX5 uses voltage channels A, B, and C as differential inputs with channel A usi

Strona 11

18 Split Phase and Open Delta For either of these two power connections, the PX5 uses only two voltage channels A and B as differential inputs with c

Strona 12

1 WARNING Death, serious injury, or fire hazard could result from improper connection of this instrument. Read and understand this manual before conne

Strona 13

19 USER INTERFACE The instrument powers up with the Home Page screen, shown above. The top portion of the screen is for status information, includ

Strona 14 - MAKING CONNECTIONS

20 In the bottom of the screen is a button for Start menu, which allows for starting to monitor from either the existing setup, recalling a stored se

Strona 15

21 REAL TIME METER MODES Scope mode Scope mode functions as an oscilloscope, displaying real-time waveforms of voltage and current for up to eight ch

Strona 16

22 Harmonics Harmonics display the amplitude and phase of each harmonic to the 63rd harmonic in both graphical and textual format. User can select whi

Strona 17 - 3 Phase, Four Wire Wye

23 STORED DATA FUNCTIONS and DISPLAYS Trend Users can generate plots for all journalled data combined with min/max recordings of that parameter. Most

Strona 18

24 Waveforms from transient event capture Detailed information of transient event capture

Strona 19 - Split Phase and Open Delta

25 List of events with characteristics

Strona 20 - USER INTERFACE

26 REPORTS There are two types of reports – EN50160 for Quality of Supply reporting, and the Annunciator panel, which the user can select to display

Strona 21 - OTHER INSTRUMENT SETUP

27 ANNUNCIATOR If the parameter is outside of the normal), it will either turn yellow limits (low or high) or flashing red (very high or very low)

Strona 22 - Meter mode

28 MEASUREMENT CONNECTIONS PX5 can monitor the following power configurations: • Single phase • Split phase • 3 Phase Delta • 3 Phase Wye • 3 Phase

Strona 23 - Harmonics

2 ADVERTENCIA Una conexión incorrecta de este instrumento puede producir la muerte, lesiones graves y riesgo de incendio. Lea y entienda este manual a

Strona 24

29 MONITORING MENU Once the setup (either stored, automatic or wizard) has been completed, the user can start monitoring instantly or monitor for a

Strona 25

30 WIZARD SETUP Wizard Setup guides the user through the circuit setup step-by-step, via a series of screens prompting for information about the circu

Strona 26

31 Includes automatic detection and comparison of wiring versus selected configuration

Strona 27 - REPORTS

32 MONITORING MODES Monitoring modes PX5 allows users to monitor events in the following setup categories: Standard Power Quality, Current Inrush

Strona 28 - ANNUNCIATOR

33 a Compact Flash data card in real time, then rearm and be ready to capture data during the next test run. Fault Recorder: A fault in a wire circui

Strona 29 - AUTOMATIC SETUP

34 EVENT CAPTURE and JOURNAL SETTINGS The transient limits for instantaneous peak, high frequency transient (PX5 only), waveshape deviation and wave

Strona 31 - WIZARD SETUP

36 The cross trigger matrix determines which channels are saved when a given channel determines that an event has occurred. SITE NAME and MEMORY C

Strona 32

37 Example of Power Quality setup using the Wizard Current Probe Select the current probes you are going to use from the list. If you are using LEMFl

Strona 33 - Monitoring modes

38 Memory Card Name your survey. The Site Name will be your data file name. Format your memory card as long as other data files are saved on your PC

Strona 34

3 AVERTISSEMENT Si l'instrument est mal connecté, la mort, des blessures graves, ou un danger d'incendie peuvent s'en suivre. Lisez att

Strona 35

39 General Specifications Dimensions Size: 12” Width x 2.5” Height x 8” Depth (30 x 6.4 x 20.3 cm) Weight: 4.2 pounds (1.9 kg) Envir

Strona 36

40 Statements and Notices Statement of warranty All products of Dranetz are warranted to the original purchaser against defective material and workma

Strona 37

41 Notice regarding proprietary rights This publication contains information proprietary to Dranetz. By accepting and using this manual, you agree th

Strona 40 - General Specifications

4 WARNUNG Der falsche Anschluß dieses Gerätes kann Tod, schwere Verletzungen oder Feuer verursachen. Bevor Sie dieses Instrument anschließen, müssen S

Strona 41 - Statements and Notices

5 Safety Summary Definitions WARNING statements inform the user that certain conditions or practices could result in loss of life or physical harm.

Strona 42

6 Safety Precautions The following safety precautions must be followed whenever any type of voltage or current connection is being made to the instrum

Strona 43

7 TABLE OF CONTENTS Introduction …………………………………….…… 8 Connect to AC Power Source ………………………… 9 Making Connections…………….……………………… 11 Connectin

Strona 44

8 Introduction The Dranetz PowerXplorer® PX5, Power Guide 4400, and the Power Visa are three portable, hand-held, eight-channel power quality meter/m